About AIRNow | AIRNow Partners | FAQs | Contact Us
Search:
Zip Code:
State:

Frequent Questions

How does AirNow report current conditions, and how does this relate to the NowCast?

AirNow’s “current conditions” and Current AQI (Air Quality Index) maps update hourly using readings from thousands of monitors across the country.

By definition, the AQI is calculated using data from a 24-hour period. That’s because the science we have about air pollution exposure and health is based on 24 hours and therefore EPA’s air quality standards are based on 24 hours. It is not valid to use shorter-term (e.g. hourly) data to calculate an AQI value. However, we want to report shorter-term data to caution people in time for them to reduce their 24-hour exposure. The NowCast is EPA’s method for relating hourly data to the AQI.

The NowCast is designed to be responsive to rapidly changing air quality conditions, such as during a wildfire. The NowCast calculation uses longer averages during periods of stable air quality and shorter averages when air quality is changing rapidly. The NowCast allows AirNow’s current conditions to align more closely with what people are actually seeing or experiencing. This gives people information they can use to protect their health when air quality is poor – and help them get outdoors and get exercise when air quality is good.

Calculating the NowCast for PM

Use the past 12 hours of PM measurements in micrograms per cubic meter (μg/m³):

  1. Select the minimum and maximum PM measurements.
  2. Subtract the minimum measurement from the maximum measurement to get the range.
  3. Divide the range by the maximum measurement in the 12 hour period to get the scaled rate

of change.

  1. Subtract the scaled rate of change from 1 to get the weight factor. The weight factor must be

between .5 and 1. The minimum limit approximates a 3-hour average.

  1. If the weight factor is less than 0.5, then set it equal to 0.5.
  2. Multiply each hourly measurement by the weight factor raised to the power of the number of

hours ago the value was measured (for the current hour, the factor is raised to the zero power).

  1. Compute the NowCast by summing the products from Step 6 and dividing by the sum of the

weight factor raised to the power of the number of hours ago each value was measured.

  1. Convert this value to an AQI.

A concentration to AQI converter is available at

www.airnow.gov/index.cfm?action=resources.conc_aqi_calc.

 

Calculating the NowCast for ozone

The ozone NowCast replaces the ozone surrogate (slope/intercept method) for real time reporting.

The ozone NowCast calculation is similar to the PM NowCast calculation. It does have some slight differences, indicated by the bold text below.

  1. Compute the concentrations range (max-min) over the last 8 hours.
  2. Divide the range by the maximum concentration in the 8 hour periodto obtain the scaled rate of change.
  3. Compute the weight factor by subtracting the scaled rate from 1. There is no minimum weight factor (PM uses a minimum weight factor of 0.5). There is a maximum weight factor of 1.
  4. Multiply each hourly concentrations by the weight factor raised to the power of how many hours ago the concentration was measured (for the current hour, the factor is raised to the zero power).
  5. Compute the NowCast by summing these products and dividing by the sum of the weight factors raised to the power of how many hours ago the concentration was measured.

Missing data is handled the same way for PM and ozone: 2 of the last 3 hours of data must be valid for a NowCast calculation.

 

Have more questions? Submit a request